(Deleted)

Fixed tanks (tank-vehicles) and demountable tanks constructed before 1 January 2007 in accordance
with the requirements in force up to 31 December 2006 but which do not, however, conform to the
requirements applicable as from 1 January 2007 regarding the marking of the external design pressure
in accordance with 6.8.2.5.1, may still be used.

(Reserved)

(Reserved)

(Reserved)

Vacuum-operated waste fixed tanks (tank-vehicles) and demountable tanks constructed before 1 July
2005 in accordance with the requirements applicable up to 31 December 2004 but which do not
conform to the requirements of 6.10.3.9 applicable as from 1 January 2005, may still be used.

Fixed tanks (tank-vehicles), demountable tanks and tanks forming elements of battery-vehicles
designed and constructed in accordance with a technical code which was recognized at the time of
their construction according to the provisions of 6.8.2.7 which were applicable at that time may still
be used.

Fixed tanks (tank vehicles) and demountable tanks constructed before 1 July 2007 in accordance with
the requirements in force up to 31 December 2006, equipped with manhole cover assemblies in
accordance with the provisions of standard EN 13317:2002 referred to in the table of paragraph
6.8.2.6, applicable until 31 December 2006, including those of the figure and table B.2 of annex B of
the said standard which are no longer accepted as from 1 January 2007, or the material of which does
not meet the requirements of EN 13094:2004, paragraph 5.2, may still be used.

When the shell of a fixed tank (tank-vehicle) or demountable tank was already divided by partitions or
surge plates into sections of not more than 7 500 litres capacity before 1 January 2009, the capacity of
the shell need not be supplemented with the symbol "S" in the particulars required by 6.8.2.5.1 until
the next periodic inspection according to 6.8.2.4.2 is performed.

Notwithstanding the provisions of 4.3.2.2.4, fixed tanks (tank-vehicles) and demountable tanks
intended for the carriage of liquefied gases or refrigerated liquefied gases, which meet the applicable
construction requirements of ADR but which were divided, before 1 July 2009, by partitions or surge
plates into sections of more than 7 500 litres capacity may still be filled to more than 20% and less
than 80% of their capacity.

(Deleted)

Fixed tanks (tank-vehicles) intended for the carriage of liquefied non-toxic flammable gases
constructed before 1 July 2011 and which are equipped with non-return valves instead of internal
stop-valves and which do not conform to the requirements of 6.8.3.2.3, may still be used.

(Deleted)

Fixed tanks (tank-vehicles), demountable tanks and battery-vehicles designed and constructed in
accordance with standards applicable at the time of their construction (see 6.8.2.6 and 6.8.3.6)
according to the provisions of ADR which were applicable at that time may still be used unless
restricted by a specific transitional measure.

Fixed tanks (tank-vehicles) and demountable tanks constructed before 1 July 2011 in accordance with
the requirements of 6.8.2.2.3 in force up to 31 December 2010 but which do not, however, conform to
the requirements of 6.8.2.2.3, third paragraph, concerning the position of the flame trap or flame
arrester may still be used.