Marking of refillable UN pressure receptacles

NOTE: Marking requirements for UN metal hydride storage systems are given in 6.2.2.9 and
marking requirements for UN bundles of cylinders are given in 6.2.2.10.

Refillable UN pressure receptacles shall be marked clearly and legibly with certification, operational
and manufacturing marks. These marks shall be permanently affixed (e.g. stamped, engraved, or
etched) on the pressure receptacle. The marks shall be on the shoulder, top end or neck of the pressure
receptacle or on a permanently affixed component of the pressure receptacle (e.g. welded collar or
corrosion resistant plate welded on the outer jacket of a closed cryogenic receptacle). Except for the
UN packaging symbol, the minimum size of the marks shall be 5 mm for pressure receptacles with a
diameter greater than or equal to 140 mm and 2.5 mm for pressure receptacles with a diameter less
than 140 mm. The minimum size of the UN packaging symbol shall be 10 mm for pressure
receptacles with a diameter greater than or equal to 140 mm and 5 mm for pressure receptacles with a
diameter less than 140 mm.

The following certification marks shall be applied:
(a) The United Nations packaging symbol   
;
This symbol shall not be used for any purpose other than certifying that a packaging, a flexible
bulk container, a portable tank or a MEGC complies with the relevant requirements in
Chapter 6.1, 6.2, 6.3, 6.5, 6.6, 6.7 or 6.11;
(b) The technical standard (e.g. ISO 9809-1) used for design, manufacture and testing; 
(c) The character(s) identifying the country of approval as indicated by the distinguishing sign
used on vehicles in international road traffic2;
2 Distinguishing sign of the State of registration used on motor vehicles and trailers in international road traffic,
e.g. in accordance with the Geneva Convention on Road Traffic of 1949 or the Vienna Convention on Road Traffic of
1968.
NOTE: The country of approval shall be understood to be the country that approved the
body which inspected the individual receptacle at time of manufacture.
(d) The identity mark or stamp of the inspection body that is registered with the competent
authority of the country authorizing the marking;
(e) The date of the initial inspection, the year (four digits) followed by the month (two digits)
separated by a slash (i.e. "/");

 

 
The following operational marks shall be applied:
(f)       The test pressure in bar, preceded by the letters "PH" and followed by the letters "BAR";
 
(g) The  mass of the  empty pressure  receptacle  including all permanently attached  integral  
parts (e.g. neck ring, foot ring, etc.) in kilograms, followed by the letters "KG". This mass shall 
not include the mass of valve, valve cap or valve guard, any coating or porous material for 
acetylene. The mass shall be expressed to three significant figures rounded up to the last digit. 
For cylinders of less than 1 kg, the mass shall be expressed to two significant figures rounded up 
to the last digit. In the case of pressure receptacles for UN No. 1001 acetylene, dissolved  and UN 
No. 3374 acetylene, solvent free, at least one decimal shall be shown after the decimal point and 
two digits for pressure receptacles of less than 1 kg;
 
(h)   The minimum guaranteed wall thickness of the pressure receptacle in millimetres followed by   
the letters "MM". This mark is not required for pressure receptacles with a water capacity less 
than or equal to 1 litre or for composite cylinders or for closed cryogenic receptacles;
 
(i)    In the case of pressure receptacles for compressed gases, UN No. 1001 acetylene, dissolved,  
   and UN No. 3374 acetylene, solvent free, the working pressure in bar, preceded by the letters 
"PW". In the case of closed cryogenic receptacles, the maximum allowable working pressure preceded 
by the letters "MAWP";
 
(j)     In the case of pressure receptacles for liquefied gases and refrigerated liquefied gases, 
the     water capacity in litres expressed to three significant figures rounded down to the last 
digit, followed by the letter "L". If the value of the minimum or nominal water capacity is an 
integer, the figures after the decimal point may be neglected;
 
(k)    In the case of pressure receptacles for UN No. 1001 acetylene, dissolved, the total of the 
mass   of the empty receptacle, the fittings and accessories not removed during filling, any 
coating,  the porous material, the solvent and the saturation gas expressed to three significant 
figures rounded down to the last digit followed by the letters "KG". At least one decimal shall be 
shown after the decimal point. For pressure receptacles of less than 1 kg, the mass shall be 
expressed to two significant figures rounded down to the last digit;
 
(l)    In the case of pressure receptacles for UN No. 3374 acetylene, solvent free, the total of 
the     mass of the empty receptacle, the fittings and accessories not removed during filling, any 
coating and the porous material expressed to three significant figures rounded down to the last 
digit followed by the letters "KG". At least one decimal shall be shown after the decimal point. 
For pressure receptacles of less than 1 kg, the mass shall be expressed to two significant figures 
rounded down to the last digit;
 

The following manufacturing marks shall be applied:
(m) Identification of the cylinder thread (e.g. 25E). This mark is not required for closed cryogenic
receptacles;
(n) The manufacturer's mark registered by the competent authority. When the country of
manufacture is not the same as the country of approval, then the manufacturer's mark shall be
preceded by the character(s) identifying the country of manufacture as indicated by the
distinguishing sign used on vehicles in international road traffic2. The country mark and the
manufacturer’s mark shall be separated by a space or slash;
(o) The serial number assigned by the manufacturer;
(p) In the case of steel pressure receptacles and composite pressure receptacles with steel liner
intended for the carriage of gases with a risk of hydrogen embrittlement, the letter "H" showing
compatibility of the steel (see ISO 11114-1:2012);
(q) For composite cylinders and tubes having a limited design life, the letters "FINAL" followed
by the design life shown as the year (four digits) followed by the month (two digits) separated
by a slash (i.e. "/");
(r) For composite cylinders and tubes having a limited design life greater than 15 years and for
composite cylinders and tubes having non-limited design life, the letters "SERVICE" followed
by the date 15 years from the date of manufacture (initial inspection) shown as the year (four
digits) followed by the month (two digits) separated by a slash (i.e. "/").
NOTE: Once the initial design type has passed the service life test programme requirements
in accordance with 6.2.2.1.1 NOTE 2 or 6.2.2.1.2 NOTE 2, future production no longer
requires this initial service life mark. The initial service life mark shall be made unreadable on
cylinders and tubes of a design type that has met the service life test programme requirements.

 

The above marks shall be placed in three groups:
- Manufacturing marks shall be the top grouping and shall appear consecutively in the sequence
given in 6.2.2.7.4 except for the marks described in 6.2.2.7.4 (q) and (r) which shall be adjacent
to the periodic inspection and test marks of 6.2.2.7.7.
- The operational marks in 6.2.2.7.3 shall be the middle grouping and the test pressure (f) shall
be immediately preceded by the working pressure (i) when the latter is required.
- Certification marks shall be the bottom grouping and shall appear in the sequence given
in 6.2.2.7.2.
The following is an example of marking a cylinder.
2 Distinguishing sign of the State of registration used on motor vehicles and trailers in international road traffic,
e.g. in accordance with the Geneva Convention on Road Traffic of 1949 or the Vienna Convention on Road Traffic of
1968.

Other marks are allowed in areas other than the side wall, provided they are made in low stress areas
and are not of a size and depth that will create harmful stress concentrations. In the case of closed
cryogenic receptacles, such marks may be on a separate plate attached to the outer jacket. Such marks
shall not conflict with required marks.

In addition to the preceding marks, each refillable pressure receptacle that meets the periodic
inspection and test requirements of 6.2.2.4 shall be marked indicating:
(a) The character(s) identifying the country authorizing the body performing the periodic
inspection and test as indicated by the distinguishing sign used on vehicles in international
road traffic2. This mark is not required if this body is approved by the competent authority of
the country approving manufacture;
(b) The registered mark of the body authorised by the competent authority for performing
periodic inspection and test;
(c) The date of the periodic inspection and test, the year (two digits) followed by the month (two
digits) separated by a slash (i.e. "/" ). Four digits may be used to indicate the year.
The above marks shall appear consecutively in the sequence given.

For acetylene cylinders, with the agreement of the competent authority, the date of the most recent
periodic inspection and the stamp of the body performing the periodic inspection and test may be
engraved on a ring held on the cylinder by the valve. The ring shall be configured so that it can only
be removed by disconnecting the valve from the cylinder.

(Deleted)

Marking of non-refillable UN pressure receptacles

Non-refillable UN pressure receptacles shall be marked clearly and legibly with certification and gas
or pressure receptacle specific marks. These marks shall be permanently affixed (e.g. stencilled,
stamped, engraved, or etched) on the pressure receptacle. Except when stencilled, the marks shall be
on the shoulder, top end or neck of the pressure receptacle or on a permanently affixed component of
the pressure receptacle (e.g. welded collar). Except for the UN packaging symbol and the "DO NOT
REFILL" mark, the minimum size of the marks shall be 5 mm for pressure receptacles with a diameter
greater than or equal to 140 mm and 2.5 mm for pressure receptacles with a diameter less than 140
mm. The minimum size of the UN packaging symbol shall be 10 mm for pressure receptacles with a
diameter greater than or equal to 140 mm and 5 mm for pressure receptacles with a diameter less than
140 mm. The minimum size of the "DO NOT REFILL" mark shall be 5 mm.

The marks listed in 6.2.2.7.2 to 6.2.2.7.4 shall be applied with the exception of (g), (h) and (m). The
serial number (o) may be replaced by the batch number. In addition, the words "DO NOT REFILL" in
letters of at least 5 mm in height are required.

The requirements of 6.2.2.7.5 shall apply.
NOTE: Non-refillable pressure receptacles may, on account of their size, substitute a label for
these permanent marks.

Other marks are allowed provided they are made in low stress areas other than the side wall and are
not of a size and depth that will create harmful stress concentrations. Such marks shall not conflict
with required marks.
 
2 Distinguishing sign of the State of registration used on motor vehicles and trailers in international road traffic,
e.g. in accordance with the Geneva Convention on Road Traffic of 1949 or the Vienna Convention on Road Traffic of
1968.
Previous Matter Next Matter

adrbook.com - Copyright all rights reserved. © 2015-2018