General provisions

The installation shall be so designed, constructed and protected that it cannot provoke any unintended
ignition or short circuit under normal conditions of use of vehicles.
The electrical installation as a whole shall meet the provisions of 9.2.2.2 to 9.2.2.9 in accordance with
the table of 9.2.1.

Wiring

Cables

 
No cable in an electrical circuit shall carry a current in excess of that for which the cable is designed.
Conductors shall be adequately insulated.
The cables shall be suitable for the conditions in the area of the vehicle, such as temperature range and
fluid compatibility conditions as given in ISO 16750-4:2010 and ISO 16750-5:2010, they are intended
to be used.
The cables shall be in conformity with standard ISO 6722-1:2011 + Cor 01:2012 or ISO 6722-2:2013.
Cables shall be securely fastened and positioned to be protected against mechanical and thermal
stresses.

Additional protection

 
Cables located to the rear of the driver's cab and on trailers shall be additionally protected to minimize
any unintended ignition or short-circuit in the event of an impact or deformation.
The additional protection shall be suitable for the conditions during normal use of the vehicle.
The additional protection is complied with if multicore cables in conformity with ISO 14572:2011 are
used or one of the examples in figures 9.2.2.2.2.1 to 9.2.2.2.2.4 below or another configuration that
offers equally effective protection.
 

Fuses and circuit breakers

All circuits shall be protected by fuses or automatic circuit breakers, except for the following:
- From the starter battery to the cold start system;
- From the starter battery to the alternator;
- From the alternator to the fuse or circuit breaker box;
- From the starter battery to the starter motor;
- From the starter battery to the power control housing of the endurance braking system (see
9.2.3.1.2), if this system is electrical or electromagnetic;
- From the starter battery to the electrical lifting mechanism for lifting the bogie axle.
The above unprotected circuits shall be as short as possible.

 

Batteries

Battery terminals shall be electrically insulated or the battery shall be covered by an insulating cover.
Batteries which may develop ignitable gas and are not located under the engine bonnet, shall be fitted
in a vented box.

Lighting

Light sources with a screw cap shall not be used.

Electrical connections between motor vehicles and trailers

Electrical connections shall be designed to prevent:
- Ingress of moisture and dirt; the connected parts shall have a protection degree of at least IP
54 in accordance with IEC 60529;
- Accidental disconnection; connectors shall fulfil the requirements given in clause 5.6 of
ISO 4091:2003.

Requirements of 9.2.2.6.1 are deemed to be met:
- for connectors standardized for specific purposes according to ISO 12098:20041, ISO
7638:20031, EN 15207:20141 or ISO 25981:20081
- where the electrical connections are part of an automatic coupling system (see ECE
Regulation No.552).

Electrical connections for other purposes concerning the proper functioning of the vehicles or their
equipment may be used provided they comply with the requirements of 9.2.2.6.1.

Voltage

The nominal voltage of the electrical system shall not exceed 25V A.C. or 60V D.C.
Higher voltages are allowed in galvanically isolated parts of the electrical system provided those parts
are not located within a perimeter of at least 0.5 metres from the outside of the load compartment or
tank.
Additionally systems working on a voltage higher than 1000V A.C. or 1500V D.C. shall be integrated
in an enclosed housing.
If Xenon lights are used only those having integrated starters are allowed.
 
1 ISO 4009, referred to in this standard, need not be applied.
2 ECE Regulation No. 55 (Uniform provisions concerning the approval of mechanical coupling components of
combinations of vehicles).

Battery master switch

A switch for breaking the electrical circuits shall be placed as close to the battery as practicable. If a
single pole switch is used it shall be placed in the supply lead and not in the earth lead.

A control device to facilitate the disconnecting and reconnecting functions of the switch shall be
installed in the driver's cab. It shall be readily accessible to the driver and be distinctively marked. It
shall be protected against inadvertent operation by either adding a protective cover, by using a dual
movement control device or by other suitable means. Additional control devices may be installed
provided they are distinctively marked and protected against inadvertent operation. If the control
device(s) are electrically operated, the circuits of the control device(s) are subject to the requirements
of 9.2.2.9.