T23 PORTABLE TANK INSTRUCTION T23
This portable tank instruction applies to self-reactive substances of Class 4.1 and organic peroxides of Class 5.2. The general provisions of Section 4.2.1 and the requirements of Section 6.7.2 shall be met. The additional provisions specific to self-reactive substances of Class 4.1 and organic peroxides of Class 5.2 in 4.2.1.13 shall also be met. |
||||||||
UN No. |
Substance |
Minimum test pressure (bar) |
Minimum shell thickness (mm- reference steel) |
Bottom opening requi- rements |
Pressure- relief requi- rements |
Degree of filling |
Control tempe- rature |
Emergency temperature |
3109 |
ORGANIC PEROXIDE, TYPE F, LIQUID tert-Butyl hydro- peroxidea, not more than 72% with water Cumyl hydro-peroxide, not more than 90% in diluent type A Di-tert-butyl peroxide, not more than 32% in diluent type A Isopropyl cumyl hydro- peroxide, not more than 72% in diluent type A p-Menthyl hydro- peroxide, not more than 72% in diluent type A Pinanyl hydro- peroxide, not more than 56% in diluent type A |
4 |
See 6.7.2.4.2 |
See 6.7.2.6.3 |
See 6.7.2.8.2 4.2.1.13.6 4.2.1.13.7 4.2.1.13.8 |
See 4.2.1.13.13 |
||
3110 |
ORGANIC PEROXIDE TYPE F, SOLID |
4 |
See 6.7.2.4.2 |
See 6.7.2.6.3 |
See 6.7.2.8.2 4.2.1.13.6 4.2.1.13.7 4.2.1.13.8 |
See 4.2.1.13.13 |
||
3119 |
ORGANIC PEROXIDE, TYPE F, LIQUID, TEMPERATURE CONTROLLED |
4 |
See 6.7.2.4.2 |
See 6.7.2.6.3 |
See 6.7.2.8.2 4.2.1.13.6 4.2.1.13.7 4.2.1.13.8 |
See 4.2.1.13.13 |
||
tert-Amyl peroxyneodecanoate, not more than 47% in diluent type A |
-10 °C |
-5 °C |
||||||
tert-Butyl peroxyacetate, not more than 32% in diluent type B |
+30 °C |
+35 °C |
||||||
tert-Butyl peroxy-2- ethylhexanoate, not more than 32% in diluent type B |
+15 °C |
+20 °C |
T23 PORTABLE TANK INSTRUCTION (cont'd) T23
This portable tank instruction applies to self-reactive substances of Class 4.1 and organic peroxides of Class 5.2. The general provisions of Section 4.2.1 and the requirements of Section 6.7.2 shall be met. The additional provisions specific to self-reactive substances of Class 4.1 and organic peroxides of Class 5.2 in 4.2.1.13 shall also be met. |
||||||||
UN No. |
Substance |
Minimum test pressure (bar) |
Minimum shell thickness (mm- reference steel) |
Bottom opening requi- rements |
Pressure- relief requi- rements |
Degree of filling |
Control tempe- rature |
Emergency temperature |
3119 (Cont'd) |
tert-Butyl peroxypivalate, not more than 27% in diluent type B |
+5 °C |
+10 °C |
|||||
tert-Butyl peroxy- 3,5,5-trimethyl- hexanoate, not more than 32% in diluent type B |
+35 °C |
+40 °C |
||||||
Di-(3,5,5-trimethyl- hexanoyl) peroxide, not more than 38% in diluent type A or type B |
0 °C |
+5 °C |
||||||
+30 C |
+35 C |
|||||||
3120 |
ORGANIC PEROXIDE, TYPE F, SOLID, TEMPERATURE CONTROLLED |
4 |
See 6.7.2.4.2 |
See 6.7.2.6.3 |
See 6.7.2.8.2 4.2.1.13.6 4.2.1.13.7 4.2.1.13.8 |
See 4.2.1.13.13 |
c |
c |
3229 |
SELF-REACTIVE LIQUID TYPE F |
4 |
See 6.7.2.4.2 |
See 6.7.2.6.3 |
See 6.7.2.8.2 4.2.1.13.6 4.2.1.13.7 4.2.1.13.8 |
See 4.2.1.13.13 |
||
3230 |
SELF-REACTIVE SOLID TYPE F |
4 |
See 6.7.2.4.2 |
See 6.7.2.6.3 |
See 6.7.2.8.2 4.2.1.13.6 4.2.1.13.7 4.2.1.13.8 |
See 4.2.1.13.13 |
||
3239 |
SELF-REACTIVE LIQUID TYPE F, TEMPERATURE CONTROLLED |
4 |
See 6.7.2.4.2 |
See 6.7.2.6.3 |
See 6.7.2.8.2 4.2.1.13.6 4.2.1.13.7 4.2.1.13.8 |
See 4.2.1.13.13 |
c |
c |
3240 |
SELF-REACTIVE SOLID TYPE F, TEMPERATURE CONTROLLED |
4 |
See 6.7.2.4.2 |
See 6.7.2.6.3 |
See 6.7.2.8.2 4.2.1.13.6 4.2.1.13.7 4.2.1.13.8 |
See 4.2.1.13.13 |
c |
c |
d Formulation derived from distillation of peroxyacetic acid originating from peroxyacetic acid in concentration of not more than 41% with water, total active oxygen (Peroxyacetic acid+H2O2) 9.5%, which fulfils the criteria of the Manual of Tests and Criteria, paragraph 20.4.3 (f). "CORROSIVE" subsidiary risk placard required (Model No 8, see 5.2.2.2.2).