Fittings and accessories mounted in the
upper part of the tank shall be either:
- inserted in a recessed housing; or
- equipped with an internal safety valve;
or
- shielded by a cap, or by transverse
and/or longitudinal members, or by
other equally effective devices, so
profiled that in the event of
overturning the fittings and accessories
will not be damaged.
Fittings and accessories mounted in the
lower part of the tank:
Pipe-sockets, lateral shut-off devices, and
all discharge devices shall either be
recessed by at least 200 mm from the
extreme outer edge of the tank or be
protected by a rail having a coefficient of
inertia of not less than 20 cm3 transversally
to the direction of travel; their ground
clearance shall be not less than 300 mm
with the tank full.
Fittings and accessories mounted on the rear
face of the tank shall be protected by the
bumper prescribed in 9.7.6. Their height
above the ground shall be such that they
                                                                 
 