Dangerous Goods by Road

373

Neutron radiation detectors containing non-pressurized boron trifluoride gas may be carried
under this entry provided that the following conditions are met:
(a) Each radiation detector shall meet the following conditions.
(i) The pressure in each detector shall not exceed 105 kPa absolute at 20 °C;
(ii) The amount of gas shall not exceed 13 g per detector;
(iii) Each detector shall be manufactured under a registered quality assurance
programme;
NOTE: ISO 9001 may be used for this purpose.
(iv) Each neutron radiation detector shall be of welded metal construction with
brazed metal to ceramic feed through assemblies. These detectors shall have a
minimum burst pressure of 1800 kPa as demonstrated by design type
qualification testing; and
(v) Each detector shall be tested to a 1 x 10-10 cm3/s leaktightness standard before
filling.
(b) Radiation detectors carried as individual components shall be carried as follows:
(i) Detectors shall be packed in a sealed intermediate plastics liner with sufficient
absorbent or adsorbent material to absorb or adsorb the entire gas contents;
(ii) They shall be packed in strong outer packaging. The completed package shall be
capable of withstanding a 1.8 m drop test without leakage of gas contents from
detectors;
(iii) The total amount of gas from all detectors per outer packaging shall not exceed
52 g.
(c) Completed neutron radiation detection systems containing detectors meeting the
conditions of paragraph (a) shall be carried as follows:
(i) The detectors shall be contained in a strong sealed outer casing;
(ii) The casing shall contain sufficient absorbent or adsorbent material to absorb or
adsorb the entire gas contents;
(iii) The completed systems shall be packed in strong outer packagings capable of
withstanding a 1.8 m drop test without leakage unless a system’s outer casing
affords equivalent protection.
Packing instruction P200 of 4.1.4.1 is not applicable.
The transport document shall include the following statement "Transport in accordance with
special provision 373".
Neutron radiation detectors containing not more than 1 g of boron trifluoride, including those
with solder glass joints, are not subject to ADR provided they meet the requirements in
paragraph (a) and are packed in accordance with paragraph (b). Radiation detection systems
containing such detectors are not subject to ADR provided they are packed in accordance with
paragraph (c).

adrbook.com - Copyright all rights reserved. © 2015-2017