Dangerous Goods by Road

P208

P208

PACKING INSTRUCTION

P208

This instruction applies to Class 2 adsorbed gases.

  1. The following packagings are authorized provided the general packing requirements of 4.1.6.1 are met: Cylinders specified in Chapter 6.2 and in accordance with ISO 11513:2011 or ISO 9809-1:2010.

  2. The pressure of each filled cylinder shall be less than 101.3 kPa at 20 C and less than 300 kPa at 50 C.

  3. The minimum test pressure of the cylinder shall be 21 bar.

  4. The minimum burst pressure of the cylinder shall be 94.5 bar.

  5. The internal pressure at 65 C of the filled cylinder shall not exceed the test pressure of the cylinder.

  6. The adsorbent material shall be compatible with the cylinder and shall not form harmful or dangerous compounds with the gas to be adsorbed. The gas in combination with the adsorbent material shall not affect or weaken the cylinder or cause a dangerous reaction (e.g. a catalyzing reaction).

  7. The quality of the adsorbent material shall be verified at the time of each fill to ensure that the pressure and chemical stability requirements of this packing instruction are met each time an adsorbed gas package is offered for carriage.

  8. The adsorbent material shall not meet the criteria of any of the classes in ADR.

  9. Requirements for cylinders and closures containing toxic gases with an LC50 less than or equal to 200 ml/m3(ppm) (see Table 1) shall be as follows:

    1. Valve outlets shall be fitted with pressure retaining gas-tight plugs or caps having threads matching those of the valve outlets.

    2. Each valve shall either be of the packless type with non-perforated diaphragm, or be of a type which prevents leakage through or past the packing.

    3. Each cylinder and closure shall be tested for leakage after filling.

    4. Each valve shall be capable of withstanding the test pressure of the cylinder and be directly connected to the cylinder by either a taper-thread or other means which meets the requirements of ISO 10692-2:2001.

    5. Cylinders and valves shall not be fitted with a pressure relief device.

  10. Valve outlets for cylinders containing pyrophoric gases shall be fitted with gas-tight plugs or caps having threads matching those of the valve outlets.

  11. The filling procedure shall be in accordance with Annex A of ISO 11513:2011.

  12. The maximum period for periodic inspections shall be 5 years.

  13. Special packing provisions that are specific to a substance (see Table 1).

Material compatibility

a: Aluminium alloy cylinders shall not be used.

d: When steel cylinders are used, only those bearing the "H" mark in accordance with 6.2.2.7.4 (p) are permitted.

Gas specific provisions

r: The filling of this gas shall be limited such that, if complete decomposition occurs, the pressure does not exceed two thirds of the test pressure of the cylinder.

Material compatibility for n.o.s. adsorbed gas entries

z: The construction materials of the cylinders and their accessories shall be compatible with the contents and shall not react to form harmful or dangerous compounds therewith.

(Cont'd on next page)

P208

PACKING INSTRUCTION (cont'd)

 

P208

Table 1: ADSORBED GASES

 

UN

No.

 

Name and description

 

Classification code

LC50

ml/m3

Special packing provisions

3510

ADSORBED GAS, FLAMMABLE, N.O.S.

9F

 

z

3511

ADSORBED GAS, N.O.S.

9A

 

z

3512

ADSORBED GAS, TOXIC, N.O.S.

9T

≤ 5000

z

3513

ADSORBED GAS, OXIDIZING, N.O.S.

9O

 

z

3514

ADSORBED GAS, TOXIC, FLAMMABLE, N.O.S.

9TF

≤ 5000

z

3515

ADSORBED GAS, TOXIC, OXIDIZING, N.O.S.

9TO

≤ 5000

z

3516

ADSORBED GAS, TOXIC, CORROSIVE, N.O.S.

9TC

≤ 5000

z

3517

ADSORBED GAS, TOXIC, FLAMMABLE, CORROSIVE, N.O.S.

9TFC

≤ 5000

z

3518

ADSORBED GAS, TOXIC, OXIDIZING, CORROSIVE, N.O.S.

9TOC

≤ 5000

z

3519

BORON TRIFLUORIDE, ADSORBED

9TC

387

a

3520

CHLORINE, ADSORBED

9TOC

293

a

3521

SILICON TETRAFLUORIDE, ADSORBED

9TC

450

a

3522

ARSINE, ADSORBED

9TF

20

d

3523

GERMANE, ADSORBED

9TF

620

d, r

3524

PHOSPHORUS PENTAFLUORIDE, ADSORBED

9TC

190

 

3525

PHOSPHINE, ADSORBED

9TF

20

d

3526

HYDROGEN SELENIDE, ADSORBED

9TF

2

 

 

adrbook.com - Copyright all rights reserved. © 2015-2017