UN No |
Name and description | Class | Classification code | Packing group | Labels | Special provisions | Limited and excepted quantities | Packaging | Portable tanks and bulk containers | ADR tank | Vehicle for tank carriage | Transport category | Special provisions for carriage | Hazard identification No. | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3.1.2 | 2.2 | 2.2 | 2.1.1.3 | 5.2.2 | 3.3 | 3.4 | 3.5.1.2 | Packing instructions
4.1.4 |
Special packing provisions 4.1.4 |
Mixed packing provisions 4.1.10 |
Instructions 4.2.5.2 7.3.2 |
Special provisions 4.2.5.3 |
Tank code 4.3 |
Special provisions 4.3.5 6.8.4 |
9.1.1.2 | (Tunnel restriction code) 1.1.3.6 (8.6) |
Packages 7.2.4 |
Bulk 7.3.3 |
Loading, unloading and handling 7.5.11 |
Operation 8.5 |
5.3.2.3 | |
(1) | (2) | (3a) | (3b) | (4) | (5) | (6) | (7a) | (7b) | (8) | (9a) | (9b) | (10) | (11) | (12) | (13) | (14) | (15) | (16) | (17) | (18) | (19) | (20) |
1133 | ADHESIVES containing flammable liquid (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 5 L | E1 | P001
R001 |
PP1 | MP19 | 3
(E) |
S2 | ||||||||||
1133 | ADHESIVES containing flammable liquid (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 5 L | E1 | P001
IBC02 R001 |
PP1
BB4 |
MP19 | 3
(E) |
S2 | ||||||||||
1139 | COATING SOLUTION (includes surface treatments or coatings used for industrial or other purposes such as vehicle under coating, drum or barrel lining) (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than | 3 | F1 | III | 3 | 5 L | E1 | P001
R001 |
PP1
BB4 |
MP19 | 3
(E) |
S2 | ||||||||||
1139 | COATING SOLUTION (includes surface treatments or coatings used for industrial or other purposes such as vehicle under coating, drum or barrel lining) (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more | 3 | F1 | III | 3 | 5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 | ||||||||||
1169 | EXTRACTS, AROMATIC, LIQUID (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 601 | 5 L | E1 | P001
R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1169 | EXTRACTS, AROMATIC, LIQUID (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 601 | 5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1197 | EXTRACTS, FLAVOURING, LIQUID (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 601 | 5 L | E1 | P001
R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1197 | EXTRACTS, FLAVOURING, LIQUID (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 601 | 5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1210 | PRINTING INK, flammable or PRINTING INK RELATED MATERIAL (including printing ink thinning or reducing compound), flammable (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 163
367 |
5 L | E1 | P001
R001 |
PP1 | MP19 | 3
(E) |
S2 | |||||||||
1210 | PRINTING INK, flammable or PRINTING INK RELATED MATERIAL (including printing ink thinning or reducing compound), flammable (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 163
367 |
5 L | E1 | P001
IBC02 R001 |
PP1
BB4 |
MP19 | 3
(E) |
S2 | |||||||||
1263 | PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL (including paint thinning and reducing compound) (having a flash-point below 23 °C and viscous according to 2.2.3.1. | 3 | F1 | III | 3 | 163
367 650 |
5 L | E1 | P001
R001 |
PP1 | MP19 | 3
(E) |
S2 | |||||||||
1263 | PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL (including paint thinning and reducing compound) (having a flash-point below 23 °C and viscous according to 2.2.3.1. | 3 | F1 | III | 3 | 163
367 650 |
5 L | E1 | P001
IBC02 R001 |
PP1
BB4 |
MP19 | 3
(E) |
S2 | |||||||||
1266 | PERFUMERY PRODUCTS with flammable solvents (having a flash- point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
R001 |
PP1
BB4 |
MP19 | 3
(E) |
S2 | |||||||||
1266 | PERFUMERY PRODUCTS with flammable solvents (having a flash- point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1286 | ROSIN OIL (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1286 | ROSIN OIL (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1287 | RUBBER SOLUTION (havinga flash point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1287 | RUBBER SOLUTION (havinga flash point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1306 | WOOD PRESERVATIVES, LIQUID (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1306 | WOOD PRESERVATIVES, LIQUID (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1866 | RESIN SOLUTION, flammable (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
R001 |
PP1 | MP19 | 3
(E) |
S2 | |||||||||
1866 | RESIN SOLUTION, flammable (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 163 | 5 L | E1 | P001
IBC02 R001 |
PP1
BB4 |
MP19 | 3
(E) |
S2 | |||||||||
1993 | FLAMMABLE LIQUID, N.O.S. (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 274
601 |
5 L | E1 | P001
R001 |
PP1
BB4 |
MP19 | 3
(E) |
S2 | |||||||||
1993 | FLAMMABLE LIQUID, N.O.S. (having a flash-point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 274
601 |
5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1999 | TARS, LIQUID, including road oils, and cutback bitumens (having a flash- point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C more than 110 kPa) | 3 | F1 | III | 3 | 274
601 |
5 L | E1 | P001
R001 |
BB4 | MP19 | 3
(E) |
S2 | |||||||||
1999 | TARS, LIQUID, including road oils, and cutback bitumens (having a flash- point below 23 °C and viscous according to 2.2.3.1.4) (vapour pressure at 50 °C not more than 110 kPa) | 3 | F1 | III | 3 | 274
601 |
5 L | E1 | P001
IBC02 R001 |
BB4 | MP19 | 3
(E) |
S2 |