The following standard applies for the design, construction, and initial inspection and test of UN metal hydride storage systems, except that inspection requirements related to the conformity assessment system and approval shall be in accordance with 6.2.2.5:

Reference Title
Applicable for
manufacture
ISO 16111:2008
Transportable gas storage devices – Hydrogen absorbed
in reversible metal hydride
Until further
notice
 

 

The standard shown below applies to the design, construction and initial inspection and test of UN bundles of cylinders. Each cylinder in a UN bundle of cylinders shall be a UN cylinder complying with the requirements of 6.2.2. The inspection requirements related to the conformity assessment system and approval for UN bundles of cylinders shall be in accordance with 6.2.2.5.

Reference Title
Applicable for
manufacture
ISO 10961:2010
Gas cylinders – Cylinder bundles – Design,
manufacture, testing and inspection
Until further
notice
 
 
NOTE: Changing one or more cylinders of the same design type, including the same test pressure, in
an existing UN bundle of cylinders does not require re-certification of the existing bundle.

The following standards apply to the design, construction and initial inspection and test of
UN cylinders for adsorbed gases except that the inspection requirements related to the conformity
assessment system and approval shall be in accordance with 6.2.2.5.
 

Reference

Title

Applicable for manufacture

ISO 11513:2011

Gas cylinders – Refillable welded steel cylinders containing materials for sub-atmospheric gas packaging (excluding acetylene) – Design, construction, testing, use and periodic inspection

Until further notice

ISO 9809-1:2010

Gas cylinders – Refillable seamless steel gas cylinders

– Design, construction and testing – Part 1: Quenched and tempered steel cylinders with tensile strength less than 1 100 MPa

Until further notice

 

Materials

In addition to the material requirements specified in the pressure receptacle design and construction
standards, and any restrictions specified in the applicable packing instruction for the gas(es) to be
carried (e.g. packing instruction P200 or P205 of 4.1.4.1), the following standards apply to material
compatibility:
 
 

ISO 11114-1:2012

Gas cylinders – Compatibility of cylinder and valve materials with gas contents – Part 1: Metallic materials

ISO 11114-2:2013

Gas cylinders – Compatibility of cylinder and valve materials with gas contents – Part 2: Non-metallic materials

 

Service equipment

The following standards apply to closures and their protection:

 

Reference

Title

Applicable for manufacture

ISO 11117:1998

Gas cylinders – Valve protection caps and valve guards for industrial and medical gas cylinders – Design, construction and tests

Until 31

December 2014

ISO 11117:2008 +

Cor 1:2009

Gas cylinders − Valve protection caps and valve guards

− Design, construction and tests

Until further notice

ISO 10297:1999

Gas cylinders – Refillable gas cylinder valves – Specification and type testing

Until 31

December 2008

ISO 10297:2006

Gas cylinders – Refillable gas cylinder valves – Specification and type testing

Until 31

December 2020

ISO 10297:2014

Gas cylinders – Cylinder valves – Specification and type testing

Until further notice

ISO 13340:2001

Transportable gas cylinders – Cylinder valves for non- refillable cylinders – Specification and prototype testing

Until further notice

 

For UN metal hydride storage systems, the requirements specified in the following standard apply to closures and their protection:

 

Reference

Title

Applicable for manufacture

ISO 16111:2008

Transportable gas storage devices – Hydrogen absorbed in reversible metal hydride

Until further notice

 

Periodic inspection and test

The following standards apply to the periodic inspection and testing of UN cylinders and UN metal
hydride storage systems:
 
 

Reference

Title

Applicable

ISO 6406:2005

Periodic inspection and testing of seamless steel gas cylinders

Until further notice

ISO 10460:2005

Gas cylinders – Welded carbon-steel gas cylinders – Periodic inspection and testing

NOTE: The repair of welds described in clause 12.1 of this standard shall not be permitted. Repairs described in clause 12.2 require the approval of the competent authority which approved the periodic inspection and test body in accordance with 6.2.2.6.

Until further notice

ISO 10461:2005 + A1:2006

Seamless aluminium-alloy gas cylinders – Periodic inspection and testing

Until further notice

ISO 10462:2005

Gas cylinders – Transportable cylinders for dissolved acetylene – Periodic inspection and maintenance

Until 31

December 2018

ISO 10462:2013

Gas cylinders – Acetylene cylinders – Periodic inspection and maintenance

Until further notice

ISO 11513:2011

Gas cylinders – Refillable welded steel cylinders containing materials for sub-atmospheric gas packaging (excluding acetylene) – Design, construction, testing, use and periodic inspection

Until further notice

ISO 11623:2002

Transportable gas cylinders – Periodic inspection and testing of composite gas cylinders

Until further notice

ISO 16111:2008

Transportable gas storage devices – Hydrogen absorbed in reversible metal hydride

Until further notice

 

Conformity assessment system and approval for manufacture of pressure receptacles

Definitions

For the purposes of this sub-section:
Conformity assessment system means a system for competent authority approval of a manufacturer, by
pressure receptacle design type approval, approval of manufacturer's quality system and approval of
inspection bodies;
Design type means a pressure receptacle design as specified by a particular pressure receptacle
standard;
Verify means confirm by examination or provision of objective evidence that specified requirements
have been fulfilled.

General requirements

Competent authority

The competent authority that approves the pressure receptacle shall approve the conformity
assessment system for the purpose of ensuring that pressure receptacles conform to the requirements
of ADR. In instances where the competent authority that approves a pressure receptacle is not the
competent authority in the country of manufacture, the marks of the approval country and the country
of manufacture shall be indicated in the pressure receptacle marks (see 6.2.2.7 and 6.2.2.8).
The competent authority of the country of approval shall supply, upon request, evidence
demonstrating compliance to this conformity assessment system to its counterpart in a country of use.

The competent authority may delegate its functions in this conformity assessment system in whole or
in part.

The competent authority shall ensure that a current list of approved inspection bodies and their
identity marks and approved manufacturers and their identity marks is available.

Inspection body

The inspection body shall be approved by the competent authority for the inspection of pressure
receptacles and shall:
(a) Have a staff with an organizational structure, capable, trained, competent, and skilled, to
satisfactorily perform its technical functions;
(b) Have access to suitable and adequate facilities and equipment;
(c) Operate in an impartial manner and be free from any influence which could prevent it from
doing so;
(d) Ensure commercial confidentiality of the commercial and proprietary activities of the
manufacturer and other bodies;
(e) Maintain clear demarcation between actual inspection body functions and unrelated
functions;
(f) Operate a documented quality system;
(g) Ensure that the tests and inspections specified in the relevant pressure receptacle standard and
ADR are performed; and
(h) Maintain an effective and appropriate report and record system in accordance with 6.2.2.5.6.

The inspection body shall perform design type approval, pressure receptacle production testing and
inspection, and certification to verify conformity with the relevant pressure receptacle standard
(see 6.2.2.5.4 and 6.2.2.5.5).

Manufacturer

 
The manufacturer shall:
(a)         Operate a documented quality system in accordance with 6.2.2.5.3;
 
(b)         Apply for design type approvals in accordance with 6.2.2.5.4;
 
(c)  Select an inspection body from the list of approved inspection bodies maintained by the   
competent authority in the country of approval; and
 
(d)         Maintain records in accordance with 6.2.2.5.6.
 